ACTIVE STANDARD: ASTM D1998-06 Standard Specification for Polyethylene Upright Storage Tanks


CLICK
HERE For standard specifications for Polyethylene Upright Storage Plastic Tanks

1. Scope
1.1 This specification covers flat-bottom, upright, cylindrical tanks molded in one-piece seamless construction by rotational molding. The tanks are molded from polyethylene for above ground, vertical installation and are capable of containing aggressive chemicals at atmospheric pressure. Included are requirements for materials, properties, design, construction, dimensions, tolerances, workmanship and appearance. Tank capacities are from 1900 L [500 gal] up.
1.2 This specification does not cover the design of vessels intended for use at pressures other than atmospheric pressure. Furthermore, this specification does not cover the design of portable tanks. It is also not for vessels intended for use with liquids heated above their flash points, or temperatures above 66C [150°F] for Type I tanks and 60°C [140°F] for Type II tanks for continuous service. NFPA Standards 30 and 31 shall be consulted for installations that are subject to the requirements of these standards.
1.3 Special design considerations not covered in this specification shall be given to vessels subject to superimposed mechanical forces, such as seismic forces, wind load or agitation; to vessels subject to service temperature in excess of 23°C [73.4°F]; and vessels subject to superimposed pressure exceeding 25.4 cm [10 in.] of water or 2.5 10 3 MPa [0.36 psi].
1.4 The values stated in SI units are to be regarded as the standard. The values given in brackets are for information only. There is no similar or equivalent ISO standard.
The following precautionary caveat pertains only to the test methods portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


2. Referenced Documents

D1693 Test Method for Environmental Stress-Cracking of Ethylene Plastics
D2837 Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials or Pressure Design Basis for Thermoplastic Pipe Products
D3892 Practice for Packaging/Packing of Plastics
D4703 Practice for Compression Molding Thermoplastic Materials into Test Specimens, Plaques, or Sheets
D618 Practice for Conditioning Plastics for Testing
D883 Terminology Relating to Plastics
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
F412 Terminology Relating to Plastic Piping Systems
2.3
2.4
29 CFR 1910.106 Occupational Safety and Health Administration, Flammable and Combustible Liquids
30 Flammable and Combustible Liquid Code
31 Installation of Oil Burning Equipment
B-16.5 Pipe Flanges and Flanged Fittings



MAIL TO LINE PIPE
CLICK HERE for Standard Terms and Conditions of Sales
CLICK
HERE For standard specifications for Polyethylene Upright Storage Plastic Tanks
CLICK
HERE for Engineers Document

corrosion and Chemical Resistant Polyethylene and  Fiberglass Tanks

Contact Our Tank Expert

CONTACT US
Sierra Sales
SERVING the WORLD of TANKS
Building the TANKs Industry Requires

RAPID RESPONSE QUOTE

|PRODUCTS PAGE| |DOWNLOADS PAGE| |BULK CONTAINERS| |VERTICAL CONTAINERS| |ENGINEERS PAGE|
SERVING the WORLD of TANKS - AMERICAN MADE PE TANKS

DHTML Menu / JavaScript Menu - Created Using NavStudio (OpenCube Inc.)